LIGO Document E1300428-x0
- Repository for Output Faraday Isolator Test Results
The repository contains an email L1000120 discussing the micro-roughness of the TGG crystals, a calculation of the suspension blades under load in T1000558, a Certificate of Conformance C1301597 from Karl Lambrecht Corp. for the polarizing prisms, measurements on a first article OFI T1300419 of the transmission and isolation ratio, measurements of wavefront error and extinction for LLO, LHO and 3 rd IFO OFIs (E1300389, E1300390 and E1400436), a table of measurements made on LLO OFI T1300342, a certificate of conformance from Karl Lambrecht Corp. T1300346 for a Brewster polarizer, a certificate of conformance from Elewctro-Optics Technology, Inc. T1300347 for a Faraday TGG crystal, reflectance measurements T1300789 on an OFI wedge prism and wavefront measurements T1300792 on a polarized.