The adhesives which are used in the Modules are:
1) Henkel/Hysol Eccobond CE3103WLV (electrically conductive):
T glass transition = 114C
T operating = 150C
Not in the NASA outgassing database
2) Epotek H70E-4 (thermally conductive)
T glass transition = 80C
T operating = 200C continuous (300C intermittent)
NASA outgassing database: has data for various cure temperatures and times. Ranges are as follows:
60C to 130C cure
40 to 360 min cure
1.23 to 4.73 %TML (total mass loss)
0.01 to 0.26 %CVCM (collected volatile condensable materials)
0.17 to 0.44 %WVR (water vapor regained)
See the comparison to %CVCM values for other LIGO approved polymer materials in the abstract for this DCC entry: E1200994. Generally .00 to .01 %CVCM
DCC Version 3.5.1, contact
DCC Help