LIGO Document T1800447-v7
- DRD for frequency dependent squeezing in A+
- v5/v6 includes updates/corrections following review E1900223
v7 incorporates the coating design, derivation of the phase noise req's on RLF, and baffle diffraction requirements.
Note added by Norna re vertical isolation of HSTSs for the filter cavity. The baseline choice of 90dB worth of Faraday isolation, corresponding to the green curves in figure 5, shows that additional passive vertical damping (i.e. over and above what the current design of HSTS gives) is not necessary.
DCC Version 3.5.0, contact