LIGO Document D1000749-v3
Home
Recent Changes
Topics
Login
Trillium 240 Interface
Document #:
LIGO-D1000749-v3
Document type:
D - Drawings
Other Versions:
LIGO-D1000749-v2
28 Apr 2011, 10:00
LIGO-D1000749-v1
29 Mar 2010, 16:03
Abstract:
Board used to interface a Trillium 240 to the LIGO readout system.
Files in Document:
Trillium_Interfacev3.pdf
(1.5 MB)
Other Files:
Altium packaged project files.
(Trillium_Interface (6-26-2014 11-34-15 AM).zip, 620.7 kB)
odb++, BOM, gerber, and pick-n-place files
(TrilliumInterfacev3.zip, 318.3 kB)
ICS/JIRA Record:
ICS_LINK
Topics:
Seismic Isolation
Authors:
Benjamin Abbott
Keywords:
T240
Trillium
sei
seismic
BSC
ISI
Notes and Changes:
v2 corrected a Tx/Rx flip, and v3 raised the value of the resistors in the pressure sensor readout chain to stop them from saturating.
Referenced by:
LIGO-D1001872-v1:
Trillium 240 Interface Chassis Back Board
LIGO-D1002694-v1:
Trillium 240 Interface Chassis
LIGO-T1300173-v1:
SEI Electronics Document Hub
LIGO-D1001575-v10:
aLIGO SEI (Seismic) Sensor (Sensors) and Actuator (Actuators) Electronics Chains