Panel too thick for TNC bulkheads listed in BOM.
The TNC bulkhead Amphenol 122168 for LMR-195 supports a maximum panel thickness of 6.5mm and is well suited for this panel when paired with the TE 330620 Insulating Bushing.
BOM:
- 2x Keystone 9106 Handle
- 4x Keystone 9121 Ferrule
- 4x McMaster-Carr 91772A146Pan Head Phillips Screw, 6-32 Thread, 3/8" Long
-16x TE 330620 Insulating Bushing
- 8x Field Components TNCFBH-LMR100-SMAM-0.58 TNC Female Bulkhead on LMR100 to SMA Male, 7" length
- 2x Amphenol 122346 Isolated TNC bulkhead adapter jack-jack