LIGO Document E1000678-v1
- The height of the optical lever transmitter and receiver relative to the global axes is determined in the Zemax optical layout (see related documents below). The locations of the optical lever transmitter and receiver are exported from Zemax and transformed into local (gravity aligned) coordinates and then the height above the floor is determined.
- WARNING: The floor height relative to the vertex in the LVEA was measured for LHO and LLO. I have only assumed that the same floor height applies in the end stations at each site -- this should be measured! (... or may have already been measured by the OpLev group).
DCC Version 3.5.0, contact