LIGO Document P070126-x0

Experimental investigation of a control scheme for a zero-detuning resonant sideband extraction interferometer for next-generation gravitational-wave detectors

Document #:
LIGO-P070126-x0
Document type:
P - Publications
Abstract:
Some next-generation gravitational-wave detectors, such as the American Advanced LIGO project and the Japanese LCGT project, plan to use power recycled resonant sideband extraction (RSE) interferometers for their interferometer's optical configuration. A power recycled zero-detuning (PRZD) RSE interferometer, which is the default design for LCGT, has five main length degrees of freedom that need to be controlled in order to operate a gravitational-wave detector. This task is expected to be very challenging because of the complexity of optical configuration. A new control scheme for a PRZD RSE interferometer has been developed and tested with a prototype interferometer. The PRZD RSE interferometer was successfully locked with the control scheme. It is the first experimental demonstration of a PRZD RSE interferometer with suspended test masses. The result serves as an important step for the operation of LCGT.
Files in Document:
Other Files:
Notes and Changes:

Rev P070126-00-Z:
- Full document number: LIGO-P070126-00-Z
- Author(s): Fumiko Kawazoe; Shuichi Sato; Volker Leonhardt; Osamu Miyakawa; Tomoko Morioka; Atsushi Nishizawa; Toshitaka Yamazaki; Mitsuhiro Fukushima; Seiji Kawamura; Akio Sugamoto
- Document date: 2007-10-18
- Document received date: 2007-10-18
- Document entry date: 2007-10-18
Journal References:
Published in Class Quant Grav vol. 25 pg. 195008 (12pp).

DCC Version 3.5.0, contact DCC Help