LIGO Document T1700302-v2

Timing Witness Signals Indicate Trustworthy Timing for Candidate G275404

Document #:
LIGO-T1700302-v2
Document type:
T - Technical notes
Other Versions:
Abstract:
Advanced LIGO data is taken by a DAQ that is directly driven in hardware by the Advanced LIGO Timing Distribution System that ensures end-to-end hardware- based timing signal integrity between the received GPS signal and the ADC boards. The Advanced LIGO Timing Diagnostic System is a separate additional hardware that provides additional layers of timing information and crosschecks to enable us to have versatile diagnostic information.
As an extra precaution, we examined the timing witness signals to ensure that the aLIGO datastream’s timing was perfect around Event Candidate G275404, observed at 1172082639= Sat Feb 25 18:30:21 UTC 2017. We found that the DuoTone witness indicated excellent timing performance on the sub-microsecond level and the IRIG-B signals indicated precise second decoding.
Files in Document:
Notes and Changes:
Wrong event file uploaded previously; deleted it in this rev

DCC Version 3.5.0, contact DCC Help