LIGO Document G1200774-v13

Global longitudinal quad damping vs. local damping

Document #:
LIGO-G1200774-v13
Document type:
G - Presentations (eg Graphics)
Other Versions:
LIGO-G1200774-v15
14 Oct 2014, 03:22
LIGO-G1200774-v8
09 Nov 2012, 11:35
LIGO-G1200774-v1
31 Jul 2012, 10:46
Abstract:
Shows how we can decouple damping noise from cavity signals by damping suspension along global ifo coordinates rather than local coordinates.
The cavity control itself can be used to apply damping along the differential cavity DOF. The common mode dynamics, invisible to the cavity, can be damped by applying the same signals to each suspension. This decoupling depends on the pendulums being nearly identical.
Files in Document:
  • G1200774-v13 (Global Damping vs Local Damping - G1200774-v13.pdf, 10.1 MB)
Other Files:
  • G1200774-v13 (Global Damping vs Local Damping - G1200774-v13.pptx, 12.8 MB)
Topics:
Authors:
Notes and Changes:
Added results of damping LHO MC2 using the IMC cavity signal.
Related Documents:

DCC Version 3.4.2, contact Document Database Administrators