PUNCH LIST - 1) It is noted that it is not always obviously clear (in test results) if X1 result is LHO or 3rd IFO. It is clear in text. No action.
SIGNED - Calum Torrie signature on 2nd April 2014 closes this Acceptance Doc on behalf of chair and committee .
Punchlist items and their resolution will be tracked in T1400181. They will not be updated on this Acceptance Document filecard.
II. Documents for Review (against list from M1100282)
Top Assembly Name:
DOES NOT EXIST YET
QUESTION TO REVIEWERS - Will systems be creating layouts for I1? Or do we "accept" it without it?
ACCEPT WITHOUT. CIT. SYSTEMS WILL NOT BE CREATING I1 LAYOUT AT THIS POINT.
ICS Assembly #:
- ICS Assembly Load:
https://ics-redux.ligo-la.caltech.edu/JIRA/browse/ASSY-D0900295-003
Acceptance document:
This filecard serves as the acceptance document for 3rd IFO OMCS.
For common material for all OMC suspensions, see
https://dcc.ligo.org/LIGO-E1201043
ICS inventory
ACTION - All to "find" an item and comment on success and structure
CHECKED. PRESENT. NICE PICTURE.
S-numbers
Electronics for I1 have been inventoried, but Rack Layouts and/or individual S numbers have not yet been assigned to specific HSTSs.
QUESTION TO REVIEWERS - Is this OK? Should we dig up chassis test reports performed by CDS? I think chassis are being stored in Racks in the H2 Electronics Room; seems like we could treat them as though that was their "installed" location, and treat the inventory as LLO has with a DCC tree structure.
ACCEPT WITHOUT. CIT.
Test results:
- Calibrated, M1toM1 Transfer Functions (DAMPING ON/OFF):
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=8191
- Calibrated OSEM Sensor ASDs, All Stages (DAMPING ON/OFF):
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=8191
- B&K Hammer Cage Resonance Transfer Functions:
DOES NOT EXIST YET (Not a part of Phase 1 Testing)
- Coil Driver Noise: TBD
- Coil Driver Response in all states: https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=4495
- Violin Mode Frequencies and Q:
Summary of modeled violin modes: https://dcc.ligo.org/LIGO-T1300876
This summary includes the predicted violin mode frequencies. Measuring the violin modes for the OMCS is not a requirement and we have no plans to do so.
Channel/Signal List and Calibrations
For latest measurements of OSEM Sensor's Open Light Current, See https://dcc.ligo.org/LIGO-E1200343
Otherwise calibrations are assumed to be as shown in OMCS Control Design Description,
https://dcc.ligo.org/LIGO-T1300535 with a roughly 20% uncertainty
III. General notes and action items:
- The review team should review E1201043 in detail - unless the SUS Acceptance format changes and E1201043 is no longer the preferred method of presenting this info. TBD.
DCC Version 3.5.1, contact
DCC Help